T-Vault continuous rooflights

Technical data

T-Vault in opal diffused

T-Vault in opal diffused

Vertical and horizontal forces

Vertical and horizontal forces

Performance

The system has a very high resistance against chemical influences and weather conditions and carries a 20 year hailproof guarantee. Fire tests have been carried out and the units are certified according to EN 1187.

Performance of GRP glazing
Typical valuesStandardFire retardant
Fire rating to BS 476: Part 3ABAA
Fire rating to BS 476: Part 7Class 3Class 1
Service temperature-50 to +120°C-50 to +120°C
Resistance to wind loadClass 2Class 2
Air permeabilityClass 2Class 2
Resistance to water penetrationClass 9aClass 9a
Impact test1200 J1200 J
Wind driven rain/snow 600PaPassPass
Curb angle

On the long sides the curb top should be splayed as noted in the table below. Curbs at each end of the rooflight should be horizontal.

Span (m)1.01.52.02.53.03.54.0
Angle10°15°20°25°30°35°40°